Water hardness in New Philadelphia, OH
Water in New Philadelphia is very hard, with a median of 362 mg/L (21.1 grains per gallon) across 108 monitoring sites within 10 miles.
New Philadelphia tap water at a glance
- HardnessVery hard (362 mg/L, 21.1 gpg, local measurements). Water softeners are common at this level.Size a water softener →
- PFASNone found in EPA's nationwide testing of the main water system.PFAS results →
- Lead pipesNo known lead lines; 7,185 lines are still of unknown material.Check your own pipe →
- ViolationsNo health-based violations since 2016.EPA record →
Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?
What 362 mg/L means at home
- Water softener: Scale build-up is likely. A water softener is commonly used to protect plumbing, water heaters and appliances.
- Dishwasher: set the water hardness to about 21.1 gpg (20.3 °dH), which is a high or maximum hardness setting, with dishwasher salt if your model takes it.
- Kettles and coffee makers: descale every 1–2 months with citric acid or vinegar.
- Laundry and soap: hard water reduces lather, so you may need more detergent, or a softener.
- Water heater: flush the tank once a year to clear sediment and scale.
Size a softener for your home → Hard water and your water heater →
Where the number comes from
Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it
Water softener and dishwasher calculator for New Philadelphia
Prefilled with New Philadelphia's measured local hardness of 362 mg/L (21.2 gpg). If your water bill or utility report gives a different number, enter it instead.
Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter
PFAS in New Philadelphia tap water
New Philadelphia City PWS is the main public water system for New Philadelphia. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 2 samples taken Apr 2023 – Oct 2023. No PFAS were found at or above EPA's minimum reporting levels.
Other water systems serving parts of New Philadelphia
| Water system | PFAS detected | Highest PFOA / PFOS | Tested |
|---|---|---|---|
| Dover City PWS serves over 10,000 people | None detected | — | Sep 2023 – Mar 2024 |
What these PFAS levels mean → Which water filters remove PFAS →
Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology
Lead pipes in New Philadelphia
New Philadelphia City PWS reported 8,386 service lines (the pipes connecting homes to the water main) in its inventory. 0 are lead and 347 are galvanized lines that must be replaced, and 7,185 are still of unknown material.
EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask New Philadelphia City PWS whether your address is on its list.
Other water systems serving parts of New Philadelphia
| Water system | Service lines | Total |
|---|---|---|
| Dover City PWS | 0 lead · 0 galvanized · 0 unknown | 5,592 |
How to tell if your home has a lead pipe → Lead pipes in every state →
As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology
New Philadelphia drinking water violations
EPA records show no health-based violations for New Philadelphia City PWS since 2016. It also had 2 monitoring or reporting violations (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.
Other water systems serving parts of New Philadelphia
| Water system | Health-based violations | Monitoring/reporting |
|---|---|---|
| Dover City PWS | None | 4 |
Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology
Monitoring sites closest to New Philadelphia
| Site | Type | Distance | Median | Samples | Years |
|---|---|---|---|---|---|
| TUSCARAWAS R. AT NEW PHILADELPHIA @ BROADWAY AVE Division of Surface water (Ohio) (State) | River/Stream | 0.6 mi | 292 mg/L | 16 | 2012–2017 |
| TUSCARAWAS R. NEAR NEW PHILADELPHIA @ U.S. RT. 250 Division of Surface water (Ohio) (State) | River/Stream | 1.1 mi | 232 mg/L | 8 | 2003–2004 |
| TUSCARAWAS R. NEAR NEW PHILADELPHIA, 1.0 MI DST U.S. RT. 250 Division of Surface water (Ohio) (State) | River/Stream | 1.6 mi | 295 mg/L | 8 | 2017–2021 |
| OLDTOWN CREEK W OF SCHOENBRUNN @ GOSHEN HILL RD. Division of Surface water (Ohio) (State) | River/Stream | 1.8 mi | 512 mg/L | 6 | 2017 |
| OLDTOWN CREEK W OF SCHOENBRUNN @ ST. RT. 416 Division of Surface water (Ohio) (State) | River/Stream | 1.9 mi | 524 mg/L | 6 | 2003–2004 |
| TUSCARAWAS R. AT NEW PHILADELPHIA @ HIGH AVE. Division of Surface water (Ohio) (State) | River/Stream | 1.9 mi | 252 mg/L | 18 | 2003–2012 |
Water hardness in towns near New Philadelphia
| Town | Distance | Median | Class |
|---|---|---|---|
| Dover | 4 mi | 361 mg/L | Very hard |
| Massillon | 21 mi | 288 mg/L | Very hard |
| Canton | 23 mi | 324 mg/L | Very hard |
| Coshocton | 26 mi | 234 mg/L | Very hard |
| North Canton | 27 mi | 326 mg/L | Very hard |
| Green | 32 mi | 287 mg/L | Very hard |
| New Franklin | 33 mi | 257 mg/L | Very hard |
| Alliance | 34 mi | 282 mg/L | Very hard |
| Wooster | 34 mi | 247 mg/L | Very hard |
| Barberton | 37 mi | 247 mg/L | Very hard |
Tuscarawas County
New Philadelphia is in Tuscarawas County, where the median is 340 mg/L (very hard) across 152 sites.
See all of Tuscarawas County →New Philadelphia, OH water: common questions
Do I need a water softener in New Philadelphia?
Very likely. Water measured around New Philadelphia is 21.1 gpg (362 mg/L, measured locally), above 10.5 gpg (180 mg/L), where softeners are common. For a 3-person home that regenerates weekly, that means a softener of about 37,000 grains.Size it for your household →
Who supplies New Philadelphia's drinking water?
The main public water system serving New Philadelphia in EPA records is New Philadelphia City PWS. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →
Do I need a water filter in New Philadelphia?
Not for anything in EPA's records: no PFAS found in EPA testing, no lead service lines reported and no health-based violations since 2016. People here who use a filter usually do it for taste, such as chlorine.Chlorine taste in tap water →
Hardness scale
What to read next
- Do you need a water softener?Water here is very hard; size a softener with our calculator.
- How to tell if your home has a lead pipe7,185 service lines here are of unknown material.
- Hard water and your water heaterHow scale affects your water heater and how often to flush.
- Water hardness converterConvert mg/L to grains per gallon or °dH for your dishwasher.