Water hardness in Superior, WI
Water in Superior is moderately hard, with a median of 89 mg/L (5.2 grains per gallon) across 9 monitoring sites within 10 miles.
Superior tap water at a glance
- HardnessModerately hard (89 mg/L, 5.2 gpg, local measurements). Some scale; descale kettles and flush the water heater.Water heater care →
- PFASNone found in EPA's nationwide testing of the main water system.PFAS results →
- Lead pipesThe water system reported 4,497 lead service lines.Check your own pipe →
- Violations2 health-based violations since 2016.What they were →
Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?
What 89 mg/L means at home
- Water softener: Most homes do not need a softener. You may notice light spotting on glass and fixtures.
- Dishwasher: set the water hardness to about 5.2 gpg (5 °dH), which is a low-to-medium hardness setting.
- Kettles and coffee makers: descaling every 3–6 months is usually enough.
- Laundry and soap: soap lathers easily and detergent goes further.
- Water heater: routine flushing every 2–3 years is typically fine.
Where the number comes from
Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it
Water softener and dishwasher calculator for Superior
Prefilled with Superior's measured local hardness of 89 mg/L (5.2 gpg). If your water bill or utility report gives a different number, enter it instead.
Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter
PFAS in Superior tap water
Superior Water Light & Power Company is the main public water system for Superior. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 4 samples taken Mar 2023 – Dec 2023. No PFAS were found at or above EPA's minimum reporting levels.
What these PFAS levels mean → Which water filters remove PFAS →
Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology
Lead pipes in Superior
Superior Water Light & Power Company reported 10,710 service lines (the pipes connecting homes to the water main) in its inventory. 4,497 are lead and 113 are galvanized lines that must be replaced, and 360 are still of unknown material.
EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask Superior Water Light & Power Company whether your address is on its list.
How to tell if your home has a lead pipe → Lead pipes in every state →
As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology
Superior drinking water violations
EPA records show 2 health-based violations for Superior Water Light & Power Company since 2016, all since resolved or closed. The most recent began in Oct 2024. It also had 1 monitoring or reporting violation (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.
| Contaminant or rule | Type | Violations | Most recent | Status |
|---|---|---|---|---|
| Lead and Copper Rule Revisions lead service line inventory and lead rule requirements | Treatment requirement not met | 1 | Oct 2024 | Resolved/closed |
| Total trihalomethanes (TTHM) byproducts formed when chlorine reacts with natural matter in water · what it means highest measured 80.9 UG/L; limit 0.080 mg/L | Contaminant above legal limit | 1 | Jan 2018 | Resolved/closed |
Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology
Monitoring sites closest to Superior
| Site | Type | Distance | Median | Samples | Years |
|---|---|---|---|---|---|
| Duluth/Superior Harbor Minnesota Pollution Control Agency - Ambient Surface Water (State) | Lake | 2.4 mi | 79 mg/L | 11 | 2025 |
| St. Louis R at Woodstock Bay nr Superior, WI USGS Minnesota Water Science Center | Lake, Reservoir, Impoundment | 3.1 mi | 76 mg/L | 2 | 2016–2017 |
| St. Louis R at Kelly Bay nr Superior, WI USGS Minnesota Water Science Center | Lake, Reservoir, Impoundment | 3.3 mi | 80 mg/L | 1 | 2017 |
| St. Louis R at Pokegama Bay nr Superior, WI USGS Minnesota Water Science Center | Lake, Reservoir, Impoundment | 3.9 mi | 90 mg/L | 6 | 2016–2017 |
| St. Louis River Outlet upstream of John A. Blatnik Memorial Bridge Minnesota Pollution Control Agency - Ambient Surface Water (State) | Lake | 4.1 mi | 82 mg/L | 10 | 2025 |
| NEMADJI R AT WI CR-C, 6 MI S OF SUPERIOR, WI Minnesota Pollution Control Agency - Ambient Surface Water (State) | River/Stream | 4.1 mi | 89 mg/L | 13 | 2008–2023 |
Water hardness in towns near Superior
| Town | Distance | Median | Class |
|---|---|---|---|
| New Richmond | 110 mi | 134 mg/L | Hard |
| Hudson | 123 mi | 96 mg/L | Moderately hard |
| Menomonie | 125 mi | 104 mg/L | Moderately hard |
| Chippewa Falls | 126 mi | 53 mg/L | Soft |
| River Falls | 129 mi | 159 mg/L | Hard |
| Eau Claire | 133 mi | 70 mg/L | Moderately hard |
| Wausau | 167 mi | 51 mg/L | Soft |
| Marshfield | 168 mi | 209 mg/L | Very hard |
| Weston | 174 mi | 46 mg/L | Soft |
| Holmen | 192 mi | 134 mg/L | Hard |
Douglas County
Superior is in Douglas County, where the median is 81 mg/L (moderately hard) across 12 sites.
See all of Douglas County →Superior, WI water: common questions
Do I need a water softener in Superior?
Probably not. Water measured around Superior is 5.2 gpg (89 mg/L, measured locally), under the 7 gpg (120 mg/L) level where scale on fixtures and appliances becomes noticeable. If spotting bothers you, about 9,000 grains of capacity covers a 3-person home between weekly regenerations.Size it for your household →
Who supplies Superior's drinking water?
The main public water system serving Superior in EPA records is Superior Water Light & Power Company. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →
Do I need a water filter in Superior?
It depends on what you want to remove. In Superior, the system reports 4,497 lead service lines; if your home has one, a filter certified to remove lead is the usual step until the line is replaced; the system had 2 health-based violations since 2016, for the Lead and Copper Rule Revisions and TTHM; the utility's annual report says what was done about them. On the other hand, no PFAS found in EPA testing. A water softener is not a filter.Check your own service line →
Hardness scale
What to read next
- How to tell if your home has a lead pipe4,497 lead service lines are reported here.
- TTHM in drinking waterDisinfection byproducts appear in this system's violation record.
- Water hardness converterConvert mg/L to grains per gallon or °dH for your dishwasher.