Water hardness in Grandview, WA

Water in Grandview is moderately hard, with a median of 103 mg/L (6 grains per gallon) across 6 monitoring sites within 10 miles.

39% harder than the Washington median (74 mg/L) 12th hardest of 122 Washington towns Population 11,149
103mg/L
6 grains per gallon
Moderately hard

Grandview tap water at a glance

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 103 mg/L means at home

  • Water softener: Most homes do not need a softener. You may notice light spotting on glass and fixtures.
  • Dishwasher: set the water hardness to about 6 gpg (5.8 °dH), which is a low-to-medium hardness setting.
  • Kettles and coffee makers: descaling every 3–6 months is usually enough.
  • Laundry and soap: soap lathers easily and detergent goes further.
  • Water heater: routine flushing every 2–3 years is typically fine.

Where the number comes from

Monitoring sites6
Lab samples7
Sample years2000–2016
Middle 50% of sites19–164 mg/L
Groundwater (wells, springs)103 mg/L · 6 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Grandview

Prefilled with Grandview's measured local hardness of 103 mg/L (6 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Grandview tap water

City of Grandview is the main public water system for Grandview. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 18 samples taken Dec 2024 – Jul 2025. No PFAS were found at or above EPA's minimum reporting levels.

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Grandview

City of Grandview reported 3,572 service lines (the pipes connecting homes to the water main) in its inventory. It reported no known lead lines, but 2,236 lines are still of unknown material.

0lead (0%)
0galvanized requiring replacement
2,236unknown material (63%)
1,336not lead (37%)

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Grandview drinking water violations

EPA records show 1 health-based violation for City of Grandview since 2016, all since resolved or closed. The most recent began in Jan 2020. It also had 43 monitoring or reporting violations (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.

Contaminant or ruleTypeViolationsMost recentStatus
Nitrate
from fertilizer, septic systems and manure · what it means
highest measured 10.3 MG/L; limit 10 mg/L
Contaminant above legal limit 1 Jan 2020 Resolved/closed

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Grandview

SiteTypeDistanceMedianSamplesYears
09N/23E-22J01
USGS Washington Water Science Center
Well 0.6 mi164 mg/L12001
09N/23E-22L01
USGS Washington Water Science Center
Well 1.1 mi2 mg/L12001
09N/24E-29B01 PAS17
USGS Washington Water Science Center
Well 3.3 mi403 mg/L12016
10N/22E-25F03
USGS Washington Water Science Center
Well 7.5 mi10 mg/L12000
08N/24E-01J01
USGS Washington Water Science Center
Well 7.9 mi44 mg/L12000
10N/22E-26A01 PAS06
USGS Washington Water Science Center
Well 8 mi162 mg/L22000–2016

Water hardness in towns near Grandview

TownDistanceMedianClass
Sunnyside7 mi 207 mg/LVery hard
West Richland25 mi 87 mg/LModerately hard
Richland30 mi 220 mg/LVery hard
Kennewick35 mi 134 mg/LHard
Pasco38 mi 278 mg/LVery hard
Yakima39 mi 47 mg/LSoft
Ellensburg60 mi 44 mg/LSoft
Moses Lake68 mi 196 mg/LVery hard
Walla Walla76 mi 58 mg/LSoft
East Wenatchee83 mi 67 mg/LModerately hard

Yakima County

Grandview is in Yakima County, where the median is 178 mg/L (hard) across 68 sites.

See all of Yakima County →

Washington

The statewide median is 74 mg/L (moderately hard) from 890 sites.

Washington hardness map →

Grandview, WA water: common questions

Do I need a water softener in Grandview?

Probably not. Water measured around Grandview is 6 gpg (103 mg/L, measured locally), under the 7 gpg (120 mg/L) level where scale on fixtures and appliances becomes noticeable. If spotting bothers you, about 11,000 grains of capacity covers a 3-person home between weekly regenerations.Size it for your household →

Who supplies Grandview's drinking water?

The main public water system serving Grandview in EPA records is City of Grandview. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in Grandview?

It depends on what you want to remove. In Grandview, the system had 1 health-based violation since 2016, for Nitrate; the utility's annual report says what was done about it. On the other hand, no PFAS found in EPA testing and no lead service lines reported. A water softener is not a filter.How to read your water quality report →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg