Water hardness in Shreveport, LA

Water in Shreveport is very hard, with a median of 226 mg/L (13.2 grains per gallon) across 33 monitoring sites within 10 miles.

391% harder than the Louisiana median (46 mg/L) 12th hardest of 58 Louisiana towns Population 177,959
226mg/L
13.2 grains per gallon
Very hard

Large city utilities sometimes soften, blend or import water from distant reservoirs, so tap water in Shreveport can differ from local source water. Your utility's annual Consumer Confidence Report lists the exact tap value.

Shreveport tap water at a glance

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 226 mg/L means at home

  • Water softener: Scale build-up is likely. A water softener is commonly used to protect plumbing, water heaters and appliances.
  • Dishwasher: set the water hardness to about 13.2 gpg (12.7 °dH), which is a high or maximum hardness setting, with dishwasher salt if your model takes it.
  • Kettles and coffee makers: descale every 1–2 months with citric acid or vinegar.
  • Laundry and soap: hard water reduces lather, so you may need more detergent, or a softener.
  • Water heater: flush the tank once a year to clear sediment and scale.

Where the number comes from

Monitoring sites33
Lab samples379
Sample years2000–2024
Middle 50% of sites46–526 mg/L
Groundwater (wells, springs)420 mg/L · 26 sites
Surface water (rivers, lakes)56 mg/L · 7 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Shreveport

Prefilled with Shreveport's measured local hardness of 226 mg/L (13.2 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Shreveport tap water

Shreveport Water System is the main public water system for Shreveport. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 4 samples taken Jun 2023 – Mar 2024. 1 PFAS was detected.

ChemicalHighest resultDetected inEPA limit
PFBA
perfluorobutanoic acid
7.5 ppt 3 of 4 samples —

Other water systems serving parts of Shreveport

Water systemPFAS detectedHighest PFOA / PFOSTested
City of Bossier City Water System
serves over 10,000 people
None detected — Apr 2023 – Jan 2024

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Shreveport

Shreveport Water System reported 92,293 service lines (the pipes connecting homes to the water main) in its inventory. 1,799 are lead and 0 are galvanized lines that must be replaced, and 85,680 are still of unknown material.

1,799lead (2%)
0galvanized requiring replacement
85,680unknown material (93%)
4,814not lead (5%)

EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask Shreveport Water System whether your address is on its list.

Other water systems serving parts of Shreveport

Water systemService linesTotal
City of Bossier City Water System0 lead · 0 galvanized · 18,350 unknown27,001

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Shreveport drinking water violations

EPA records show 23 health-based violations for Shreveport Water System since 2016, all since resolved or closed. The most recent began in Jan 2026. It also had 1 monitoring or reporting violation (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.

Contaminant or ruleTypeViolationsMost recentStatus
Surface water treatment (filtration/turbidity)
filtration requirements that protect against microbes such as Cryptosporidium
Treatment requirement not met 10 Jan 2026 Resolved/closed
Total trihalomethanes (TTHM)
byproducts formed when chlorine reacts with natural matter in water · what it means
highest measured 0.157 MG/L; limit 0.080 mg/L
Contaminant above legal limit 7 Jan 2026 Resolved/closed
Surface Water Treatment Rule
filtration and disinfection of river and lake water
Treatment requirement not met 5 Mar 2025 Resolved/closed
Chlorite
a byproduct of chlorine dioxide disinfection
highest measured 1.207 MG/L; limit 1.0 mg/L
Contaminant above legal limit 1 Jun 2016 Resolved/closed

Other water systems serving parts of Shreveport

Water systemHealth-based violationsMonitoring/reporting
City of Bossier City Water SystemNone1

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Shreveport

SiteTypeDistanceMedianSamplesYears
Cross Lake at Shreveport, Louisiana
LDEQ/Water Planning and Assessment (Louisiana) (State)
Lake 2.9 mi48 mg/L442008–2021
Cd-5556Z
USGS Louisiana Water Science Center
Well 4.1 mi35 mg/L12004
Cd-534P
USGS Louisiana Water Science Center
Well 4.2 mi420 mg/L12000
Cd-534
USGS Louisiana Water Science Center
Well 4.2 mi527 mg/L12000
Cross Bayou West of Bossier City, Louisiana
LDEQ/Water Planning and Assessment (Louisiana) (State)
River/Stream 4.2 mi46 mg/L462008–2021
Cd-9869Z
USGS Louisiana Water Science Center
Well 4.7 mi7 mg/L22013–2015

Water hardness in towns near Shreveport

TownDistanceMedianClass
Bossier City9 mi 183 mg/LVery hard
Minden32 mi 21 mg/LSoft
Natchitoches65 mi 116 mg/LModerately hard
Ruston68 mi 11 mg/LSoft
Claiborne93 mi 23 mg/LSoft
West Monroe96 mi 20 mg/LSoft
Monroe100 mi 22 mg/LSoft
Alexandria112 mi 40 mg/LSoft
Pineville112 mi 40 mg/LSoft
Moss Bluff153 mi 73 mg/LModerately hard

Caddo Parish

Shreveport is in Caddo Parish, where the median is 56 mg/L (soft) across 71 sites.

See all of Caddo Parish →

Louisiana

The statewide median is 46 mg/L (soft) from 1,097 sites.

Louisiana hardness map →

Shreveport, LA water: common questions

Do I need a water softener in Shreveport?

Very likely. Water measured around Shreveport is 13.2 gpg (226 mg/L, measured locally), above 10.5 gpg (180 mg/L), where softeners are common. For a 3-person home that regenerates weekly, that means a softener of about 23,000 grains.Size it for your household →

Who supplies Shreveport's drinking water?

The main public water system serving Shreveport in EPA records is Shreveport Water System. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in Shreveport?

It depends on what you want to remove. In Shreveport, EPA testing found PFBA in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS; the system reports 1,799 lead service lines; if your home has one, a filter certified to remove lead is the usual step until the line is replaced; the system had 23 health-based violations since 2016, for the Interim Enhanced Surface Water Treatment Rule and TTHM and more; the utility's annual report says what was done about them. A water softener is not a filter.Filters that remove PFAS →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next