Water hardness in Wilmington, DE

Water in Wilmington is moderately hard, with a median of 100 mg/L (5.8 grains per gallon) across 91 monitoring sites within 10 miles.

89% harder than the Delaware median (53 mg/L) 1st hardest of 11 Delaware towns Population 71,675
100mg/L
5.8 grains per gallon
Moderately hard

Wilmington tap water at a glance

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 100 mg/L means at home

  • Water softener: Most homes do not need a softener. You may notice light spotting on glass and fixtures.
  • Dishwasher: set the water hardness to about 5.8 gpg (5.6 °dH), which is a low-to-medium hardness setting.
  • Kettles and coffee makers: descaling every 3–6 months is usually enough.
  • Laundry and soap: soap lathers easily and detergent goes further.
  • Water heater: routine flushing every 2–3 years is typically fine.

Where the number comes from

Monitoring sites91
Lab samples5,256
Sample years2000–2026
Middle 50% of sites88–128 mg/L
Groundwater (wells, springs)98 mg/L · 4 sites
Surface water (rivers, lakes)102 mg/L · 87 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Wilmington

Prefilled with Wilmington's measured local hardness of 100 mg/L (5.8 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Wilmington tap water

Wilmington Water Department is the main public water system for Wilmington. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 8 samples taken Feb 2023 – Jan 2024. 6 PFAS were detected. The highest PFOA result was above EPA's drinking water limit (4 ppt).

ChemicalHighest resultDetected inEPA limit
PFPeA
perfluoropentanoic acid
32.2 ppt 8 of 8 samples —
PFHxA
perfluorohexanoic acid
21.1 ppt 8 of 8 samples —
PFBA
perfluorobutanoic acid
14.1 ppt 7 of 8 samples —
PFOA
perfluorooctanoic acid
9.9 ppt 8 of 8 samples 4 ppt
PFHpA
perfluoroheptanoic acid
8.4 ppt 5 of 8 samples —
PFBS
perfluorobutane sulfonic acid
3.6 ppt 4 of 8 samples —

Other water systems serving parts of Wilmington

Water systemPFAS detectedHighest PFOA / PFOSTested
Suez Water Delaware
serves over 10,000 people
PFBA, PFPeA, PFHxA +6 more 24.4 / ND ppt Feb 2023 – Dec 2023
Artesian Water Company
serves over 10,000 people
PFPeA, PFBA, PFHxA +5 more 23.1 / 6 ppt May 2024 – Feb 2025

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Wilmington

Wilmington Water Department reported 30,868 service lines (the pipes connecting homes to the water main) in its inventory. 1,708 are lead and 669 are galvanized lines that must be replaced, and 11,241 are still of unknown material.

1,708lead (6%)
669galvanized requiring replacement
11,241unknown material (36%)
17,250not lead (56%)

EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask Wilmington Water Department whether your address is on its list.

Other water systems serving parts of Wilmington

Water systemService linesTotal
Veolia Water Delaware, INC0 lead · 78 galvanized · 35,490 unknown40,442
Artesian Water Company148 lead · 374 galvanized · 29,413 unknown85,347

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Wilmington drinking water violations

EPA records show 1 health-based violation for Wilmington Water Department since 2016, all since resolved or closed. The most recent began in Oct 2017. It also had 1 monitoring or reporting violation (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.

Contaminant or ruleTypeViolationsMost recentStatus
Surface water treatment (Long Term 2 rule)
extra treatment or covered reservoirs to protect against microbes
Treatment requirement not met 1 Oct 2017 Resolved/closed

Other water systems serving parts of Wilmington

Water systemHealth-based violationsMonitoring/reporting
Suez Water DelawareNone0
Artesian Water CompanyNone0

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Wilmington

SiteTypeDistanceMedianSamplesYears
Shellpot CreeK @ Lea Blvd.
Delaware Dept Natural Resources & Environmental Control
River/Stream 1.5 mi124 mg/L702000–2011
Cherry Island (RM 71.0)
Delaware River Basin Commission
River/Stream 1.7 mi91 mg/L1992005–2026
Matson Run @ Lea Blvd.
Delaware Dept Natural Resources & Environmental Control
River/Stream 1.9 mi170 mg/L12006
Shellpot Creek @ Market St. (Rt. 13 Bus.)
Delaware Dept Natural Resources & Environmental Control
River/Stream 2.1 mi134 mg/L2842000–2025
Brandywine Creek @ Foot Bridge in Brandywine Park
Delaware Dept Natural Resources & Environmental Control
River/Stream 2.1 mi103 mg/L2132000–2025
Brandywine Creek near Wilmington, DE
USGS Pennsylvania Water Science Center
Stream 2.1 mi92 mg/L62008–2009

Water hardness in towns near Wilmington

TownDistanceMedianClass
Hockessin9 mi 99 mg/LModerately hard
Pike Creek Valley9 mi 94 mg/LModerately hard
Brookside10 mi 90 mg/LModerately hard
Bear11 mi 85 mg/LModerately hard
Newark13 mi 86 mg/LModerately hard
Glasgow15 mi 76 mg/LModerately hard
Middletown22 mi 68 mg/LModerately hard
Smyrna31 mi 67 mg/LModerately hard
Dover40 mi 62 mg/LModerately hard
Milford57 mi 47 mg/LSoft

New Castle County

Wilmington is in New Castle County, where the median is 90 mg/L (moderately hard) across 255 sites.

See all of New Castle County →

Delaware

The statewide median is 53 mg/L (soft) from 823 sites.

Delaware hardness map →

Wilmington, DE water: common questions

Do I need a water softener in Wilmington?

Probably not. Water measured around Wilmington is 5.8 gpg (100 mg/L, measured locally), under the 7 gpg (120 mg/L) level where scale on fixtures and appliances becomes noticeable. If spotting bothers you, about 10,000 grains of capacity covers a 3-person home between weekly regenerations.Size it for your household →

Who supplies Wilmington's drinking water?

The main public water system serving Wilmington in EPA records is Wilmington Water Department. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in Wilmington?

It depends on what you want to remove. In Wilmington, EPA testing found PFPeA, PFHxA and PFBA and 3 other PFAS in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS; the system reports 1,708 lead service lines; if your home has one, a filter certified to remove lead is the usual step until the line is replaced; the system had 1 health-based violation since 2016, for the Long Term 2 Enhanced Surface Water Treatment Rule; the utility's annual report says what was done about it. A water softener is not a filter.Filters that remove PFAS →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next