Water hardness in Newark, DE

Water in Newark is moderately hard, with a median of 86 mg/L (5 grains per gallon) across 127 monitoring sites within 10 miles.

62% harder than the Delaware median (53 mg/L) 5th hardest of 11 Delaware towns Population 30,169
86mg/L
5 grains per gallon
Moderately hard

Newark tap water at a glance

  • HardnessModerately hard (86 mg/L, 5 gpg, local measurements). Some scale; descale kettles and flush the water heater.Water heater care →
  • PFAS8 found; the highest PFOA and PFOS result was above EPA's 4 ppt limit (a single result is not a violation).Filters that remove PFAS →
  • Lead pipesNo known lead lines; 6,512 lines are still of unknown material.Check your own pipe →
  • ViolationsNo health-based violations since 2016.EPA record →

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 86 mg/L means at home

  • Water softener: Most homes do not need a softener. You may notice light spotting on glass and fixtures.
  • Dishwasher: set the water hardness to about 5 gpg (4.8 °dH), which is a low-to-medium hardness setting.
  • Kettles and coffee makers: descaling every 3–6 months is usually enough.
  • Laundry and soap: soap lathers easily and detergent goes further.
  • Water heater: routine flushing every 2–3 years is typically fine.

Where the number comes from

Monitoring sites127
Lab samples4,226
Sample years2000–2025
Middle 50% of sites62–127 mg/L
Groundwater (wells, springs)83 mg/L · 43 sites
Surface water (rivers, lakes)86 mg/L · 84 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Newark

Prefilled with Newark's measured local hardness of 86 mg/L (5 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Newark tap water

Newark Water Department is the main public water system for Newark. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 6 samples taken Mar 2023 – Dec 2023. 8 PFAS were detected. The highest PFOA and PFOS results were above EPA's drinking water limit (4 ppt).

ChemicalHighest resultDetected inEPA limit
PFOA
perfluorooctanoic acid
25.3 ppt 5 of 6 samples 4 ppt
PFHxA
perfluorohexanoic acid
13.2 ppt 6 of 6 samples —
PFPeA
perfluoropentanoic acid
12.6 ppt 5 of 6 samples —
PFBA
perfluorobutanoic acid
11.2 ppt 2 of 6 samples —
PFHpA
perfluoroheptanoic acid
7.9 ppt 2 of 6 samples —
PFOS
perfluorooctane sulfonic acid
7.5 ppt 2 of 6 samples 4 ppt
PFBS
perfluorobutane sulfonic acid
6.6 ppt 2 of 6 samples —
PFHxS
perfluorohexane sulfonic acid
5.5 ppt 2 of 6 samples 10 ppt*

Other water systems serving parts of Newark

Water systemPFAS detectedHighest PFOA / PFOSTested
Artesian Water Company
serves over 10,000 people
PFPeA, PFBA, PFHxA +5 more 23.1 / 6 ppt May 2024 – Feb 2025
Suez Water Delaware
serves over 10,000 people
PFBA, PFPeA, PFHxA +6 more 24.4 / ND ppt Feb 2023 – Dec 2023
Wilmington Water Department
serves over 10,000 people
PFPeA, PFHxA, PFBA +3 more 9.9 / ND ppt Feb 2023 – Jan 2024

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Newark

Newark Water Department reported 8,962 service lines (the pipes connecting homes to the water main) in its inventory. 0 are lead and 1 are galvanized lines that must be replaced, and 6,512 are still of unknown material.

0lead (0%)
1galvanized requiring replacement
6,512unknown material (73%)
2,449not lead (27%)

EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask Newark Water Department whether your address is on its list.

Other water systems serving parts of Newark

Water systemService linesTotal
Artesian Water Company148 lead · 374 galvanized · 29,413 unknown85,347
Veolia Water Delaware, INC0 lead · 78 galvanized · 35,490 unknown40,442
Wilmington Water Department1,708 lead · 669 galvanized · 11,241 unknown30,868

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Newark drinking water violations

EPA records show no health-based violations for Newark Water Department since 2016.

Other water systems serving parts of Newark

Water systemHealth-based violationsMonitoring/reporting
Artesian Water CompanyNone0
Suez Water DelawareNone0
Wilmington Water Department11

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Newark

SiteTypeDistanceMedianSamplesYears
Christina CreeK @ Elkton Rd. (Rt.2)
Delaware Dept Natural Resources & Environmental Control
River/Stream 0.9 mi62 mg/L12006
Trib Christina Creek @ Timberline Rd.
Delaware Dept Natural Resources & Environmental Control
River/Stream 1.3 mi78 mg/L12006
White Clay Creek @ McKees Lane
Delaware Dept Natural Resources & Environmental Control
River/Stream 1.4 mi123 mg/L2082003–2025
Christina River @ Nottingham Rd. (Rt. 273)
Delaware Dept Natural Resources & Environmental Control
River/Stream 1.4 mi70 mg/L2042000–2025
Trib Christina Creek @ Valley Rd.
Delaware Dept Natural Resources & Environmental Control
River/Stream 1.6 mi77 mg/L12003
Christina CreeK @ W.Chestnut Hill Rd.
Delaware Dept Natural Resources & Environmental Control
River/Stream 1.7 mi70 mg/L22006–2011

Water hardness in towns near Newark

TownDistanceMedianClass
Brookside3 mi 90 mg/LModerately hard
Pike Creek Valley5 mi 94 mg/LModerately hard
Glasgow5 mi 76 mg/LModerately hard
Bear6 mi 85 mg/LModerately hard
Hockessin8 mi 99 mg/LModerately hard
Wilmington13 mi 100 mg/LModerately hard
Middletown16 mi 68 mg/LModerately hard
Smyrna28 mi 67 mg/LModerately hard
Dover38 mi 62 mg/LModerately hard
Milford56 mi 47 mg/LSoft

New Castle County

Newark is in New Castle County, where the median is 90 mg/L (moderately hard) across 255 sites.

See all of New Castle County →

Delaware

The statewide median is 53 mg/L (soft) from 823 sites.

Delaware hardness map →

Newark, DE water: common questions

Do I need a water softener in Newark?

Probably not. Water measured around Newark is 5 gpg (86 mg/L, measured locally), under the 7 gpg (120 mg/L) level where scale on fixtures and appliances becomes noticeable. If spotting bothers you, about 9,000 grains of capacity covers a 3-person home between weekly regenerations.Size it for your household →

Who supplies Newark's drinking water?

The main public water system serving Newark in EPA records is Newark Water Department. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in Newark?

It depends on what you want to remove. In Newark, EPA testing found PFOA, PFHxA and PFPeA and 5 other PFAS in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS. On the other hand, no lead service lines reported and no health-based violations since 2016. A water softener is not a filter.Filters that remove PFAS →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next