Water hardness in Glen Carbon, IL

Water in Glen Carbon is very hard, with a median of 416 mg/L (24.3 grains per gallon) across 20 monitoring sites within 10 miles.

42% harder than the Illinois median (293 mg/L) 3rd hardest of 225 Illinois towns Population 13,868
416mg/L
24.3 grains per gallon
Very hard

Glen Carbon tap water at a glance

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 416 mg/L means at home

  • Water softener: Scale build-up is likely. A water softener is commonly used to protect plumbing, water heaters and appliances.
  • Dishwasher: set the water hardness to about 24.3 gpg (23.3 °dH), which is a high or maximum hardness setting, with dishwasher salt if your model takes it.
  • Kettles and coffee makers: descale every 1–2 months with citric acid or vinegar.
  • Laundry and soap: hard water reduces lather, so you may need more detergent, or a softener.
  • Water heater: flush the tank once a year to clear sediment and scale.

Where the number comes from

Monitoring sites20
Lab samples149
Sample years2000–2023
Middle 50% of sites289–493 mg/L
Groundwater (wells, springs)500 mg/L · 9 sites
Surface water (rivers, lakes)290 mg/L · 11 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Glen Carbon

Prefilled with Glen Carbon's measured local hardness of 416 mg/L (24.3 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Glen Carbon tap water

The City of Glen Carbon water system is the main public water system for Glen Carbon. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 4 samples taken Aug 2023 – Jun 2024. 3 PFAS were detected.

ChemicalHighest resultDetected inEPA limit
PFBA
perfluorobutanoic acid
16 ppt 4 of 4 samples —
PFHxA
perfluorohexanoic acid
3.8 ppt 1 of 4 samples —
PFPeA
perfluoropentanoic acid
3.6 ppt 1 of 4 samples —

Other water systems serving parts of Glen Carbon

Water systemPFAS detectedHighest PFOA / PFOSTested
Edwardsville
serves over 10,000 people
PFBS — Nov 2023 – Jun 2024
IL American-Granite City
serves over 10,000 people
PFBA, PFPeA, PFHxA — Nov 2023 – Aug 2024
IL American-Alton
serves over 10,000 people
PFBA, PFHxA, PFPeA — Nov 2023 – Aug 2024
IL American-East ST Louis
serves over 10,000 people
PFBA, PFHxA, PFPeA — Nov 2023 – Aug 2024

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Glen Carbon

The City of Glen Carbon water system reported 5,588 service lines (the pipes connecting homes to the water main) in its inventory. 1 are lead and 70 are galvanized lines that must be replaced, and 151 are still of unknown material.

1lead (<1%)
70galvanized requiring replacement
151unknown material (3%)
5,366not lead (96%)

EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask the City of Glen Carbon water system whether your address is on its list.

Other water systems serving parts of Glen Carbon

Water systemService linesTotal
Edwardsville0 lead · 0 galvanized · 1,587 unknown9,185
IL American-Granite City697 lead · 130 galvanized · 12,306 unknown21,217
IL American-Alton140 lead · 374 galvanized · 7,995 unknown22,013
IL American-East ST Louis749 lead · 351 galvanized · 34,431 unknown71,163

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Glen Carbon drinking water violations

EPA records show no health-based violations for the City of Glen Carbon water system since 2016. It also had 5 monitoring or reporting violations (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.

Other water systems serving parts of Glen Carbon

Water systemHealth-based violationsMonitoring/reporting
EdwardsvilleNone1
IL American-Granite CityNone1
IL American-AltonNone0
IL American-East ST LouisNone1

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Glen Carbon

SiteTypeDistanceMedianSamplesYears
4N8W-33.2f1
USGS Illinois Water Science Center
Well 0.4 mi514 mg/L22005–2015
4N8W-27.1b1
USGS Illinois Water Science Center
Well 0.9 mi434 mg/L22005–2015
4N8W-26.4f1
USGS Illinois Water Science Center
Well 1.7 mi632 mg/L22005–2015
4N8W-22.3e1
USGS Illinois Water Science Center
Well 1.7 mi447 mg/L52005–2015
4N8W-22.7g1
USGS Illinois Water Science Center
Well 2 mi500 mg/L22005–2015
4N8W-20.4e1 (SIUE)
USGS Illinois Water Science Center
Well 2.2 mi669 mg/L22005–2015

Water hardness in towns near Glen Carbon

TownDistanceMedianClass
Edwardsville2 mi 396 mg/LVery hard
Troy6 mi 441 mg/LVery hard
Collinsville6 mi 416 mg/LVery hard
Granite City8 mi 398 mg/LVery hard
Wood River9 mi 358 mg/LVery hard
Fairview Heights11 mi 363 mg/LVery hard
O'Fallon12 mi 372 mg/LVery hard
East St. Louis13 mi 386 mg/LVery hard
Alton14 mi 328 mg/LVery hard
Swansea14 mi 368 mg/LVery hard

Madison County

Glen Carbon is in Madison County, where the median is 339 mg/L (very hard) across 34 sites.

See all of Madison County →

Illinois

The statewide median is 293 mg/L (very hard) from 1,100 sites.

Illinois hardness map →

Glen Carbon, IL water: common questions

Do I need a water softener in Glen Carbon?

Very likely. Water measured around Glen Carbon is 24.3 gpg (416 mg/L, measured locally), above 10.5 gpg (180 mg/L), where softeners are common. For a 3-person home that regenerates weekly, that means a softener of about 42,000 grains.Size it for your household →

Who supplies Glen Carbon's drinking water?

The main public water system serving Glen Carbon in EPA records is Glen Carbon. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in Glen Carbon?

It depends on what you want to remove. In Glen Carbon, EPA testing found PFBA, PFHxA and PFPeA in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS; the system reports 1 lead service lines; if your home has one, a filter certified to remove lead is the usual step until the line is replaced. On the other hand, no health-based violations since 2016. A water softener is not a filter.Filters that remove PFAS →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next