Water hardness in Manchester, CT

Water in Manchester is moderately hard, with a median of 75 mg/L (4.4 grains per gallon) across 13 monitoring sites within 10 miles.

about the same as the Connecticut median (69 mg/L) 24th hardest of 33 Connecticut towns Population 30,577 (2010)
75mg/L
4.4 grains per gallon
Moderately hard

Manchester tap water at a glance

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 75 mg/L means at home

  • Water softener: Most homes do not need a softener. You may notice light spotting on glass and fixtures.
  • Dishwasher: set the water hardness to about 4.4 gpg (4.2 °dH), which is a low-to-medium hardness setting.
  • Kettles and coffee makers: descaling every 3–6 months is usually enough.
  • Laundry and soap: soap lathers easily and detergent goes further.
  • Water heater: routine flushing every 2–3 years is typically fine.

Where the number comes from

Monitoring sites13
Lab samples610
Sample years2000–2023
Middle 50% of sites57–94 mg/L
Groundwater (wells, springs)72 mg/L · 10 sites
Surface water (rivers, lakes)94 mg/L · 3 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Manchester

Prefilled with Manchester's measured local hardness of 75 mg/L (4.4 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Manchester tap water

Manchester Water Department is the main public water system for Manchester. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 24 samples taken Oct 2023 – Jul 2024. 7 PFAS were detected. The highest PFOS and PFOA results were above EPA's drinking water limit (4 ppt).

ChemicalHighest resultDetected inEPA limit
PFOS
perfluorooctane sulfonic acid
16 ppt 6 of 24 samples 4 ppt
PFBS
perfluorobutane sulfonic acid
15 ppt 5 of 24 samples —
PFOA
perfluorooctanoic acid
13 ppt 14 of 24 samples 4 ppt
PFHxA
perfluorohexanoic acid
4.7 ppt 8 of 24 samples —
PFPeA
perfluoropentanoic acid
4.7 ppt 5 of 24 samples —
PFHxS
perfluorohexane sulfonic acid
3.8 ppt 4 of 24 samples 10 ppt*
PFHpA
perfluoroheptanoic acid
3.5 ppt 2 of 24 samples —

Other water systems serving parts of Manchester

Water systemPFAS detectedHighest PFOA / PFOSTested
CTWC - Northern Reg-Western System
serves over 10,000 people
PFOA, PFOS, PFBA +4 more 8 / 6 ppt Mar 2024 – Jul 2025
Metropolitan District Commission
serves over 10,000 people
None detected — Jan 2023 – Oct 2023

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Manchester

Manchester Water Department reported 16,093 service lines (the pipes connecting homes to the water main) in its inventory. 5 are lead and 383 are galvanized lines that must be replaced, and 10,924 are still of unknown material.

5lead (<1%)
383galvanized requiring replacement
10,924unknown material (68%)
4,781not lead (30%)

EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask Manchester Water Department whether your address is on its list.

Other water systems serving parts of Manchester

Water systemService linesTotal
CTWC - Northern Reg-Western System34 lead · 97 galvanized · 15,886 unknown39,336
Metropolitan District Commission0 lead · 43 galvanized · 14,029 unknown104,807

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Manchester drinking water violations

EPA records show no health-based violations for Manchester Water Department since 2016. It also had 4 monitoring or reporting violations (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.

Other water systems serving parts of Manchester

Water systemHealth-based violationsMonitoring/reporting
CTWC - Northern Reg-Western SystemNone2
Metropolitan District CommissionNone2

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Manchester

SiteTypeDistanceMedianSamplesYears
CT- M 195
USGS Connecticut Water Science Center
Well 1.9 mi120 mg/L22003–2017
CT- M 193
USGS Connecticut Water Science Center
Well 2.3 mi16 mg/L22003–2017
CT- M 192
USGS Connecticut Water Science Center
Well 2.6 mi24 mg/L82003–2017
CT- M 194
USGS Connecticut Water Science Center
Well 2.9 mi38 mg/L22003–2017
HOCKANUM RIVER NEAR EAST HARTFORD, CT
USGS Connecticut Water Science Center
Stream 3.5 mi94 mg/L1992000–2023
CT- SW 136
USGS Connecticut Water Science Center
Well 3.9 mi93 mg/L82003–2017

Water hardness in towns near Manchester

TownDistanceMedianClass
East Hartford5 mi 91 mg/LModerately hard
Hartford8 mi 94 mg/LModerately hard
Wethersfield9 mi 93 mg/LModerately hard
West Hartford12 mi 94 mg/LModerately hard
Windsor Locks12 mi 93 mg/LModerately hard
Newington13 mi 152 mg/LHard
Storrs14 mi 27 mg/LSoft
New Britain15 mi 152 mg/LHard
Willimantic16 mi 30 mg/LSoft
Middletown17 mi 141 mg/LHard

Capitol Planning Region

Manchester is in Capitol Planning Region, where the median is 93 mg/L (moderately hard) across 31 sites.

See all of Capitol Planning Region →

Connecticut

The statewide median is 69 mg/L (moderately hard) from 192 sites.

Connecticut hardness map →

Manchester, CT water: common questions

Do I need a water softener in Manchester?

Probably not. Water measured around Manchester is 4.4 gpg (75 mg/L, measured locally), under the 7 gpg (120 mg/L) level where scale on fixtures and appliances becomes noticeable. If spotting bothers you, about 8,000 grains of capacity covers a 3-person home between weekly regenerations.Size it for your household →

Who supplies Manchester's drinking water?

The main public water system serving Manchester in EPA records is Manchester Water Department. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in Manchester?

It depends on what you want to remove. In Manchester, EPA testing found PFOS, PFBS and PFOA and 4 other PFAS in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS; the system reports 5 lead service lines; if your home has one, a filter certified to remove lead is the usual step until the line is replaced. On the other hand, no health-based violations since 2016. A water softener is not a filter.Filters that remove PFAS →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next