Water hardness in Storrs, CT

Water in Storrs is soft, with a median of 27 mg/L (1.6 grains per gallon) across 6 monitoring sites within 10 miles.

61% softer than the Connecticut median (69 mg/L) 31st hardest of 33 Connecticut towns Population 15,344 (2010)
27mg/L
1.6 grains per gallon
Soft

Storrs tap water at a glance

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 27 mg/L means at home

  • Water softener: A water softener is generally not needed. Soft water rarely causes scale.
  • Dishwasher: set the water hardness to about 1.6 gpg (1.5 °dH), which is the lowest hardness setting (or softener off).
  • Kettles and coffee makers: descaling every 3–6 months is usually enough.
  • Laundry and soap: soap lathers easily and detergent goes further.
  • Water heater: routine flushing every 2–3 years is typically fine.

Where the number comes from

Monitoring sites6
Lab samples497
Sample years2000–2023
Middle 50% of sites22–34 mg/L
Groundwater (wells, springs)35 mg/L · 1 sites
Surface water (rivers, lakes)23 mg/L · 5 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Storrs

Prefilled with Storrs's measured local hardness of 27 mg/L (1.6 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Storrs tap water

Storrs is served by more than one water system. These systems supply ZIP codes in Storrs and were tested for PFAS ("forever chemicals") in EPA's nationwide UCMR 5 study. Check your water bill to see which one is yours.

Water systems serving Storrs

Water systemPFAS detectedHighest PFOA / PFOSTested
CTWC - Northern Reg-Western System
serves over 10,000 people
PFOA, PFOS, PFBA +4 more 8 / 6 ppt Mar 2024 – Jul 2025
University of Connecticut - Main Campus
serves over 10,000 people
PFBA, PFOS ND / 5 ppt Mar 2023 – Jun 2024

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Storrs

Storrs is served by more than one water system. Their service line inventories, as reported to EPA:

Water systems serving Storrs

Water systemService linesTotal
CTWC - Northern Reg-Western System34 lead · 97 galvanized · 15,886 unknown39,336
University of Connecticut - Main Campus0 lead · 0 galvanized · 0 unknown427

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Storrs drinking water violations

Storrs is served by more than one water system. Health-based violations recorded by EPA since 2016:

Water systems serving Storrs

Water systemHealth-based violationsMonitoring/reporting
CTWC - Northern Reg-Western SystemNone2
University of Connecticut - Main CampusNone3

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Storrs

SiteTypeDistanceMedianSamplesYears
FENTON RIVER AT MANSFIELD, CT
USGS Connecticut Water Science Center
Stream 1.7 mi31 mg/L42016
CT-MS 18
USGS Massachusetts Water Science Center
Well 3.4 mi35 mg/L22014–2023
WILLIMANTIC R AT MERROW, CT
USGS Connecticut Water Science Center
Stream 3.5 mi22 mg/L1902000–2023
MOUNT HOPE RIVER NEAR WARRENVILLE, CT
USGS Connecticut Water Science Center
Stream 4.9 mi41 mg/L42016
NATCHAUG R AT CHAPLIN CT
USGS Connecticut Water Science Center
Stream 6.9 mi18 mg/L1902000–2023
SHETUCKET R AT SOUTH WINDHAM, CT
USGS Connecticut Water Science Center
Stream 9.8 mi23 mg/L1072000–2011

Water hardness in towns near Storrs

TownDistanceMedianClass
Willimantic7 mi 30 mg/LSoft
Manchester14 mi 75 mg/LModerately hard
East Hartford19 mi 91 mg/LModerately hard
Norwich20 mi 26 mg/LSoft
Windsor Locks22 mi 93 mg/LModerately hard
Hartford22 mi 94 mg/LModerately hard
Wethersfield23 mi 93 mg/LModerately hard
West Hartford26 mi 94 mg/LModerately hard
Newington26 mi 152 mg/LHard
Middletown28 mi 141 mg/LHard

Northeastern Connecticut Planning Region

Storrs is in Northeastern Connecticut Planning Region, where the median is 33 mg/L (soft) across 13 sites.

See all of Northeastern Connecticut Planning Region →

Connecticut

The statewide median is 69 mg/L (moderately hard) from 192 sites.

Connecticut hardness map →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next