Water hardness in Texarkana, AR

Water in Texarkana is moderately hard, with a median of 89 mg/L (5.2 grains per gallon) across 4 monitoring sites within 10 miles.

51% harder than the Arkansas median (59 mg/L) 15th hardest of 39 Arkansas towns Population 29,223
89mg/L
5.2 grains per gallon
Moderately hard

Texarkana tap water at a glance

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 89 mg/L means at home

  • Water softener: Most homes do not need a softener. You may notice light spotting on glass and fixtures.
  • Dishwasher: set the water hardness to about 5.2 gpg (5 °dH), which is a low-to-medium hardness setting.
  • Kettles and coffee makers: descaling every 3–6 months is usually enough.
  • Laundry and soap: soap lathers easily and detergent goes further.
  • Water heater: routine flushing every 2–3 years is typically fine.

Where the number comes from

Monitoring sites4
Lab samples278
Sample years2000–2026
Middle 50% of sites55–148 mg/L
Surface water (rivers, lakes)89 mg/L · 4 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Texarkana

Prefilled with Texarkana's measured local hardness of 89 mg/L (5.2 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Texarkana tap water

Texarkana Water Utilities is the main public water system for Texarkana. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 4 samples taken Jun 2023 – Mar 2024. No PFAS were found at or above EPA's minimum reporting levels.

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Texarkana

Texarkana Water Utilities reported 11,041 service lines (the pipes connecting homes to the water main) in its inventory. It reported no known lead lines, but 7,616 lines are still of unknown material.

0lead (0%)
0galvanized requiring replacement
7,616unknown material (69%)
3,425not lead (31%)

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Texarkana drinking water violations

EPA records show 1 health-based violation for Texarkana Water Utilities since 2016, all since resolved or closed. The most recent began in Jan 2016.

Contaminant or ruleTypeViolationsMost recentStatus
Total trihalomethanes (TTHM)
byproducts formed when chlorine reacts with natural matter in water · what it means
highest measured 83 UG/L; limit 0.080 mg/L
Contaminant above legal limit 1 Jan 2016 Resolved/closed

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Texarkana

SiteTypeDistanceMedianSamplesYears
Nix Creek access from dirt road at the intersection of S Spruce St and S Day St.
Arkansas Department of Environmental Quality
River/Stream 3.5 mi50 mg/L222019–2020
McKinney Bayou near Mandeville on CR296/Dooley Ferry Rd
Arkansas Department of Environmental Quality
River/Stream 4.4 mi122 mg/L172000–2009
Days Creek southeast of Texarkana, Arkansas
Arkansas Department of Environmental Quality
River/Stream 8.1 mi56 mg/L1322000–2026
Red River at Index, AR
USGS Arkansas Water Science Center
Stream 8.6 mi226 mg/L1072000–2019

Water hardness in towns near Texarkana

TownDistanceMedianClass
Magnolia45 mi 14 mg/LSoft
Camden66 mi 21 mg/LSoft
Arkadelphia71 mi 16 mg/LSoft
El Dorado78 mi 27 mg/LSoft
Hot Springs90 mi 26 mg/LSoft
Malvern93 mi 23 mg/LSoft
Hot Springs Village103 mi 19 mg/LSoft
Benton113 mi 53 mg/LSoft
Bryant118 mi 58 mg/LSoft
Pine Bluff125 mi 26 mg/LSoft

Miller County

Texarkana is in Miller County, where the median is 56 mg/L (soft) across 13 sites.

See all of Miller County →

Arkansas

The statewide median is 59 mg/L (soft) from 1,916 sites.

Arkansas hardness map →

Texarkana, AR water: common questions

Do I need a water softener in Texarkana?

Probably not. Water measured around Texarkana is 5.2 gpg (89 mg/L, measured locally), under the 7 gpg (120 mg/L) level where scale on fixtures and appliances becomes noticeable. If spotting bothers you, about 9,000 grains of capacity covers a 3-person home between weekly regenerations.Size it for your household →

Who supplies Texarkana's drinking water?

The main public water system serving Texarkana in EPA records is Texarkana Water Utilities. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in Texarkana?

It depends on what you want to remove. In Texarkana, the system had 1 health-based violation since 2016, for TTHM; the utility's annual report says what was done about it. On the other hand, no PFAS found in EPA testing and no lead service lines reported. A water softener is not a filter.How to read your water quality report →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next