Water hardness in Paris, KY

Water in Paris is very hard, with a median of 212 mg/L (12.4 grains per gallon) across 3 monitoring sites within 10 miles.

66% harder than the Kentucky median (128 mg/L) 11th hardest of 35 Kentucky towns Population 10,089
212mg/L
12.4 grains per gallon
Very hard

Paris tap water at a glance

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 212 mg/L means at home

  • Water softener: Scale build-up is likely. A water softener is commonly used to protect plumbing, water heaters and appliances.
  • Dishwasher: set the water hardness to about 12.4 gpg (11.9 °dH), which is a high or maximum hardness setting, with dishwasher salt if your model takes it.
  • Kettles and coffee makers: descale every 1–2 months with citric acid or vinegar.
  • Laundry and soap: hard water reduces lather, so you may need more detergent, or a softener.
  • Water heater: flush the tank once a year to clear sediment and scale.

Where the number comes from

Monitoring sites3
Lab samples110
Sample years2000–2007
Middle 50% of sites208–252 mg/L
Surface water (rivers, lakes)212 mg/L · 3 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Paris

Prefilled with Paris's measured local hardness of 212 mg/L (12.4 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Paris tap water

Paris Water Works is the main public water system for Paris. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 4 samples taken Jan 2023 – Oct 2023. 4 PFAS were detected.

ChemicalHighest resultDetected inEPA limit
PFPeA
perfluoropentanoic acid
6.3 ppt 1 of 4 samples —
PFBA
perfluorobutanoic acid
6 ppt 1 of 4 samples —
PFHxA
perfluorohexanoic acid
3.1 ppt 1 of 4 samples —
PFBS
perfluorobutane sulfonic acid
3.1 ppt 1 of 4 samples —

Other water systems serving parts of Paris

Water systemPFAS detectedHighest PFOA / PFOSTested
Kentucky-American Water
serves over 10,000 people
6:2 FTS, PFBA, PFPeA +2 more — Mar 2023 – Dec 2023
Harrison Co Water Assoc
serves over 10,000 people
PFOS, PFHxS, PFPeA +4 more ND / 47.9 ppt Mar 2024 – Dec 2024

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Paris

Paris Water Works reported 5,779 service lines (the pipes connecting homes to the water main) in its inventory. 0 are lead and 6 are galvanized lines that must be replaced, and 3,485 are still of unknown material.

0lead (0%)
6galvanized requiring replacement
3,485unknown material (60%)
2,288not lead (40%)

EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask Paris Water Works whether your address is on its list.

Other water systems serving parts of Paris

Water systemService linesTotal
Kentucky-American Water28 lead · 39 galvanized · 69,237 unknown135,585
Harrison Co Water Assoc0 lead · 0 galvanized · 0 unknown6,716

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Paris drinking water violations

EPA records show 8 health-based violations for Paris Water Works since 2016, all since resolved or closed. The most recent began in Mar 2025. It also had 9 monitoring or reporting violations (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.

Contaminant or ruleTypeViolationsMost recentStatus
Surface water treatment (filtration/turbidity)
filtration requirements that protect against microbes such as Cryptosporidium
Treatment requirement not met 3 Mar 2025 Resolved/closed
Haloacetic acids (HAA5)
byproducts of chlorine disinfection · what it means
highest measured 0.089 MG/L; limit 0.060 mg/L
Contaminant above legal limit 5 Jan 2020 Resolved/closed

Other water systems serving parts of Paris

Water systemHealth-based violationsMonitoring/reporting
Kentucky-American WaterNone0
Harrison Co Water Assoc21

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Paris

SiteTypeDistanceMedianSamplesYears
STONER CREEK AT RUDDLES MILLS
Kentucky Division of Water
River/Stream 7.2 mi204 mg/L542000–2007
HINKSTON CREEK AT RUDDLES MILLS
Kentucky Division of Water
River/Stream 7.5 mi212 mg/L532000–2007
STRODES CREEK NEAR NORTH MIDDLETOWN
Kentucky Division of Water
River/Stream 8.1 mi292 mg/L32000

Water hardness in towns near Paris

TownDistanceMedianClass
Frankfort32 mi 175 mg/LHard
Richmond33 mi 214 mg/LVery hard
Lawrenceburg36 mi 178 mg/LHard
Berea42 mi 214 mg/LVery hard
Shelbyville52 mi 198 mg/LVery hard
Alexandria53 mi 124 mg/LHard
Florence58 mi 128 mg/LHard
La Grange61 mi 216 mg/LVery hard
Burlington62 mi 128 mg/LHard
Fort Thomas62 mi 124 mg/LHard

Bourbon County

Paris is in Bourbon County, where the median is 212 mg/L (very hard) across 3 sites.

See all of Bourbon County →

Kentucky

The statewide median is 128 mg/L (hard) from 372 sites.

Kentucky hardness map →

Paris, KY water: common questions

Do I need a water softener in Paris?

Very likely. Water measured around Paris is 12.4 gpg (212 mg/L, measured locally), above 10.5 gpg (180 mg/L), where softeners are common. For a 3-person home that regenerates weekly, that means a softener of about 22,000 grains.Size it for your household →

Who supplies Paris's drinking water?

The main public water system serving Paris in EPA records is Paris Water Works. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in Paris?

It depends on what you want to remove. In Paris, EPA testing found PFPeA, PFBA and PFHxA and 1 other PFAS in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS; the system had 8 health-based violations since 2016, for the Interim Enhanced Surface Water Treatment Rule and Total Haloacetic Acids (HAA5); the utility's annual report says what was done about them. On the other hand, no lead service lines reported. A water softener is not a filter.Filters that remove PFAS →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next