Water hardness in Keizer, OR
Water in Keizer is soft, with a median of 36 mg/L (2.1 grains per gallon) across 31 monitoring sites within 10 miles.
Keizer tap water at a glance
- HardnessSoft (36 mg/L, 2.1 gpg, local measurements). A water softener isn't needed.Water heater care →
- PFAS1 found in EPA testing; every result with a federal limit was at or below it.PFAS results →
- Lead pipesNo lead service lines reported.Details →
- ViolationsNo health-based violations since 2016.EPA record →
Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?
What 36 mg/L means at home
- Water softener: A water softener is generally not needed. Soft water rarely causes scale.
- Dishwasher: set the water hardness to about 2.1 gpg (2 °dH), which is the lowest hardness setting (or softener off).
- Kettles and coffee makers: descaling every 3–6 months is usually enough.
- Laundry and soap: soap lathers easily and detergent goes further.
- Water heater: routine flushing every 2–3 years is typically fine.
Where the number comes from
Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it
Water softener and dishwasher calculator for Keizer
Prefilled with Keizer's measured local hardness of 36 mg/L (2.1 gpg). If your water bill or utility report gives a different number, enter it instead.
Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter
PFAS in Keizer tap water
City of Keizer is the main public water system for Keizer. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 20 samples taken Jun 2024 – Mar 2025. 1 PFAS was detected. Every result with a federal limit was at or below it.
| Chemical | Highest result | Detected in | EPA limit |
|---|---|---|---|
| PFHxS perfluorohexane sulfonic acid | 3.9 ppt | 3 of 17 samples | 10 ppt* |
What these PFAS levels mean → Which water filters remove PFAS →
Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology
Lead pipes in Keizer
City of Keizer reported 10,912 service lines (the pipes connecting homes to the water main) in its inventory. It reported no lead or galvanized lines requiring replacement.
How to tell if your home has a lead pipe → Lead pipes in every state →
As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology
Keizer drinking water violations
EPA records show no health-based violations for City of Keizer since 2016. It also had 3 monitoring or reporting violations (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.
Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology
Monitoring sites closest to Keizer
| Site | Type | Distance | Median | Samples | Years |
|---|---|---|---|---|---|
| CLAGGETT CREEK AT NORTH RIVER ROAD AT KEIZER, OR USGS Oregon Water Science Center | Stream | 0.1 mi | 98 mg/L | 10 | 2015 |
| GLENN CREEK AT HARRITT DR NW, SALEM, OR USGS Oregon Water Science Center | Stream | 3.2 mi | 36 mg/L | 10 | 2015 |
| GIBSON CREEK IN BRUSH COLLEGE PARK, AT SALEM, OR USGS Oregon Water Science Center | Stream | 3.3 mi | 30 mg/L | 10 | 2015 |
| Mill Creek at Front Street NE, Salem (tributary to Willamette River at River Mile 84) Department of Environmental Quality - State of Oregon | River/Stream | 3.7 mi | 36 mg/L | 8 | 2016–2021 |
| Mid Willamette Groundwater Study Well MWV-019 Department of Environmental Quality - State of Oregon | Well | 3.9 mi | 16 mg/L | 1 | 2017 |
| Willamette River at Salem RR Bridge Department of Environmental Quality - State of Oregon | River/Stream | 4 mi | 23 mg/L | 10 | 2020–2021 |
Water hardness in towns near Keizer
| Town | Distance | Median | Class |
|---|---|---|---|
| Hayesville | 3 mi | 33 mg/L | Soft |
| Salem | 5 mi | 26 mg/L | Soft |
| Four Corners | 6 mi | 30 mg/L | Soft |
| Silverton | 12 mi | 96 mg/L | Moderately hard |
| Woodburn | 13 mi | 125 mg/L | Hard |
| Independence | 13 mi | 27 mg/L | Soft |
| Monmouth | 14 mi | 36 mg/L | Soft |
| Dallas | 15 mi | 71 mg/L | Moderately hard |
| McMinnville | 17 mi | 122 mg/L | Hard |
| Newberg | 21 mi | 99 mg/L | Moderately hard |
Marion County
Keizer is in Marion County, where the median is 44 mg/L (soft) across 71 sites.
See all of Marion County →Keizer, OR water: common questions
Do I need a water softener in Keizer?
Probably not. Water measured around Keizer is 2.1 gpg (36 mg/L, measured locally), under the 7 gpg (120 mg/L) level where scale on fixtures and appliances becomes noticeable.When a softener helps →
Who supplies Keizer's drinking water?
The main public water system serving Keizer in EPA records is City of Keizer. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →
Do I need a water filter in Keizer?
It depends on what you want to remove. In Keizer, EPA testing found PFHxS in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS. On the other hand, no lead service lines reported and no health-based violations since 2016. A water softener is not a filter.Filters that remove PFAS →
Hardness scale
What to read next
- Which water filters remove PFAS?EPA tests found 1 PFAS in Keizer's main water system.
- Water hardness converterConvert mg/L to grains per gallon or °dH for your dishwasher.