Water hardness in McAlester, OK

Water in McAlester is moderately hard, with a median of 114 mg/L (6.7 grains per gallon) across 7 monitoring sites within 10 miles.

51% softer than the Oklahoma median (231 mg/L) 41st hardest of 45 Oklahoma towns Population 18,140
114mg/L
6.7 grains per gallon
Moderately hard

McAlester tap water at a glance

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 114 mg/L means at home

  • Water softener: Most homes do not need a softener. You may notice light spotting on glass and fixtures.
  • Dishwasher: set the water hardness to about 6.7 gpg (6.4 °dH), which is a low-to-medium hardness setting.
  • Kettles and coffee makers: descaling every 3–6 months is usually enough.
  • Laundry and soap: soap lathers easily and detergent goes further.
  • Water heater: routine flushing every 2–3 years is typically fine.

Where the number comes from

Monitoring sites7
Lab samples209
Sample years2000–2025
Middle 50% of sites92–134 mg/L
Surface water (rivers, lakes)114 mg/L · 7 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for McAlester

Prefilled with McAlester's measured local hardness of 114 mg/L (6.7 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in McAlester tap water

Mcalester Pwa is the main public water system for McAlester. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 4 samples taken Nov 2024 – Aug 2025. No PFAS were found at or above EPA's minimum reporting levels.

Other water systems serving parts of McAlester

Water systemPFAS detectedHighest PFOA / PFOSTested
Adamson RWD #8
serves 10,000 people or fewer
PFBA — Jan 2025 – Dec 2025
Bryan Co. RWS & SWMD #2
serves 10,000 people or fewer
None detected — Jan 2025 – Dec 2025
Pittsburg Co. RWD #11 (Kiowa)
serves 10,000 people or fewer
PFBA — Mar 2024 – Dec 2024

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in McAlester

Mcalester Pwa reported 7,545 service lines (the pipes connecting homes to the water main) in its inventory. 0 are lead and 69 are galvanized lines that must be replaced, and 5,234 are still of unknown material.

0lead (0%)
69galvanized requiring replacement
5,234unknown material (69%)
2,242not lead (30%)

EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask Mcalester Pwa whether your address is on its list.

Other water systems serving parts of McAlester

Water systemService linesTotal
Adamson RWD #80 lead · 0 galvanized · 0 unknown1,731
Bryan Co. RWS & SWMD #20 lead · 0 galvanized · 1,087 unknown1,619
Pittsburg Co. RWD #11 (Kiowa)0 lead · 0 galvanized · 0 unknown410

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

McAlester drinking water violations

EPA records show 47 health-based violations for Mcalester Pwa since 2016, all since resolved or closed. The most recent began in Jan 2026. It also had 11 monitoring or reporting violations (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.

Contaminant or ruleTypeViolationsMost recentStatus
Total trihalomethanes (TTHM)
byproducts formed when chlorine reacts with natural matter in water · what it means
highest measured 0.087 MG/L; limit 0.080 mg/L
Contaminant above legal limit 15 Jan 2026 Resolved/closed
Lead and Copper Rule Revisions
lead service line inventory and lead rule requirements
Treatment requirement not met 1 Oct 2024 Resolved/closed
Surface water treatment (filtration/turbidity)
filtration requirements that protect against microbes such as Cryptosporidium
Treatment requirement not met 11 Jul 2024 Resolved/closed
Surface Water Treatment Rule
filtration and disinfection of river and lake water
Treatment requirement not met 5 Jul 2024 Resolved/closed
Total organic carbon removal
treatment that limits the matter disinfection byproducts form from
Treatment requirement not met 6 Jul 2023 Resolved/closed
Haloacetic acids (HAA5)
byproducts of chlorine disinfection · what it means
highest measured 0.075 MG/L; limit 0.060 mg/L
Contaminant above legal limit 9 Oct 2020 Resolved/closed

Other water systems serving parts of McAlester

Water systemHealth-based violationsMonitoring/reporting
Adamson RWD #8390
Bryan Co. RWS & SWMD #2356
Pittsburg Co. RWD #11 (Kiowa)119

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to McAlester

SiteTypeDistanceMedianSamplesYears
Unnamed Creek: Site # 011
Oklahoma Conservation Commission (State)
River/Stream 2.8 mi92 mg/L22008–2009
Unnamed Creek: Site # 011
Oklahoma Conservation Commission (State)
River/Stream 2.8 mi92 mg/L22008–2009
Coal Creek
Oklahoma Conservation Commission (State)
River/Stream 5.3 mi114 mg/L592013–2025
Coal Creek
Oklahoma Conservation Commission (State)
River/Stream 5.3 mi147 mg/L212013–2015
Peaceable Creek
Oklahoma Conservation Commission (State)
River/Stream 6.5 mi58 mg/L102000
Peaceable Creek
Oklahoma Conservation Commission (State)
River/Stream 8.5 mi144 mg/L382008–2015

Water hardness in towns near McAlester

TownDistanceMedianClass
Okmulgee49 mi 152 mg/LHard
Ada52 mi 259 mg/LVery hard
Muskogee61 mi 155 mg/LHard
Bixby71 mi 212 mg/LVery hard
Glenpool72 mi 207 mg/LVery hard
Coweta72 mi 112 mg/LModerately hard
Durant73 mi 162 mg/LHard
Shawnee74 mi 105 mg/LModerately hard
Jenks75 mi 207 mg/LVery hard
Broken Arrow77 mi 152 mg/LHard

Pittsburg County

McAlester is in Pittsburg County, where the median is 89 mg/L (moderately hard) across 18 sites.

See all of Pittsburg County →

Oklahoma

The statewide median is 231 mg/L (very hard) from 1,773 sites.

Oklahoma hardness map →

McAlester, OK water: common questions

Do I need a water softener in McAlester?

Probably not. Water measured around McAlester is 6.7 gpg (114 mg/L, measured locally), under the 7 gpg (120 mg/L) level where scale on fixtures and appliances becomes noticeable. If spotting bothers you, about 12,000 grains of capacity covers a 3-person home between weekly regenerations.Size it for your household →

Who supplies McAlester's drinking water?

The main public water system serving McAlester in EPA records is Mcalester Pwa. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in McAlester?

It depends on what you want to remove. In McAlester, the system had 47 health-based violations since 2016, for TTHM and the Lead and Copper Rule Revisions and more; the utility's annual report says what was done about them. On the other hand, no PFAS found in EPA testing and no lead service lines reported. A water softener is not a filter.How to read your water quality report →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next