Water hardness in Winona, MN
Water in Winona is very hard, with a median of 206 mg/L (12 grains per gallon) across 8 monitoring sites within 10 miles.
Winona tap water at a glance
- HardnessVery hard (206 mg/L, 12 gpg, local measurements). Water softeners are common at this level.Size a water softener →
- PFASNone found in EPA's nationwide testing of the main water system.PFAS results →
- Lead pipesNo known lead lines; 3 lines are still of unknown material.Check your own pipe →
- Violations8 health-based violations since 2016.What they were →
Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?
What 206 mg/L means at home
- Water softener: Scale build-up is likely. A water softener is commonly used to protect plumbing, water heaters and appliances.
- Dishwasher: set the water hardness to about 12 gpg (11.5 °dH), which is a high or maximum hardness setting, with dishwasher salt if your model takes it.
- Kettles and coffee makers: descale every 1–2 months with citric acid or vinegar.
- Laundry and soap: hard water reduces lather, so you may need more detergent, or a softener.
- Water heater: flush the tank once a year to clear sediment and scale.
Size a softener for your home → Hard water and your water heater →
Where the number comes from
Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it
Water softener and dishwasher calculator for Winona
Prefilled with Winona's measured local hardness of 206 mg/L (12 gpg). If your water bill or utility report gives a different number, enter it instead.
Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter
PFAS in Winona tap water
The City of Winona water system is the main public water system for Winona. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 6 samples taken Nov 2023 – Jul 2024. No PFAS were found at or above EPA's minimum reporting levels.
Other water systems serving parts of Winona
| Water system | PFAS detected | Highest PFOA / PFOS | Tested |
|---|---|---|---|
| Goodview serves 10,000 people or fewer | None detected | — | Jan 2024 – Jul 2024 |
What these PFAS levels mean → Which water filters remove PFAS →
Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology
Lead pipes in Winona
The City of Winona water system reported 8,959 service lines (the pipes connecting homes to the water main) in its inventory. 0 are lead and 2,706 are galvanized lines that must be replaced, and 3 are still of unknown material.
EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask the City of Winona water system whether your address is on its list.
Other water systems serving parts of Winona
| Water system | Service lines | Total |
|---|---|---|
| Goodview | 0 lead · 0 galvanized · 0 unknown | 1,306 |
How to tell if your home has a lead pipe → Lead pipes in every state →
As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology
Winona drinking water violations
EPA records show 8 health-based violations for the City of Winona water system since 2016, all since resolved or closed. The most recent began in Jul 2021.
| Contaminant or rule | Type | Violations | Most recent | Status |
|---|---|---|---|---|
| Radium naturally occurring radioactive element in some groundwater highest measured 9.6 PCI/L; limit 5 pCi/L | Contaminant above legal limit | 8 | Jul 2021 | Resolved/closed |
Other water systems serving parts of Winona
| Water system | Health-based violations | Monitoring/reporting |
|---|---|---|
| Goodview | None | 0 |
Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology
Monitoring sites closest to Winona
| Site | Type | Distance | Median | Samples | Years |
|---|---|---|---|---|---|
| WINONA (NORTH BAY) Minnesota Pollution Control Agency - Ambient Surface Water (State) | Lake | 1.1 mi | 159 mg/L | 1 | 2021 |
| WINONA (SOUTH BAY) Minnesota Pollution Control Agency - Ambient Surface Water (State) | Lake | 1.4 mi | 205 mg/L | 2 | 2010–2011 |
| Winona (Southeast Bay) Minnesota Pollution Control Agency - Ambient Surface Water (State) | Lake | 1.7 mi | 168 mg/L | 1 | 2021 |
| Pr Island 107N07W17AAADAD01 0000561863 USGS Minnesota Water Science Center | Well | 1.9 mi | 207 mg/L | 1 | 2013 |
| MISSISSIPPI R. BY WINONA Minnesota Pollution Control Agency - Ambient Surface Water (State) | River/Stream | 2.5 mi | 188 mg/L | 46 | 2008–2025 |
| GARVIN BK E JUST OF CSAH 23, .25 MI SW OF MINNESOTA CITY, MN Minnesota Pollution Control Agency - Ambient Surface Water (State) | River/Stream | 5.2 mi | 300 mg/L | 13 | 2010–2021 |
Water hardness in towns near Winona
| Town | Distance | Median | Class |
|---|---|---|---|
| Rochester | 40 mi | 306 mg/L | Very hard |
| Red Wing | 59 mi | 250 mg/L | Very hard |
| Austin | 70 mi | 258 mg/L | Very hard |
| Hastings | 75 mi | 270 mg/L | Very hard |
| Owatonna | 78 mi | 337 mg/L | Very hard |
| Northfield | 79 mi | 273 mg/L | Very hard |
| Cottage Grove | 81 mi | 270 mg/L | Very hard |
| Faribault | 82 mi | 192 mg/L | Very hard |
| Rosemount | 84 mi | 280 mg/L | Very hard |
| Farmington | 85 mi | 320 mg/L | Very hard |
Winona County
Winona is in Winona County, where the median is 256 mg/L (very hard) across 18 sites.
See all of Winona County →Winona, MN water: common questions
Do I need a water softener in Winona?
Very likely. Water measured around Winona is 12 gpg (206 mg/L, measured locally), above 10.5 gpg (180 mg/L), where softeners are common. For a 3-person home that regenerates weekly, that means a softener of about 21,000 grains.Size it for your household →
Who supplies Winona's drinking water?
The main public water system serving Winona in EPA records is Winona. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →
Do I need a water filter in Winona?
It depends on what you want to remove. In Winona, the system had 8 health-based violations since 2016, for Combined Radium (-226 and -228); the utility's annual report says what was done about them. On the other hand, no PFAS found in EPA testing and no lead service lines reported. A water softener is not a filter.How to read your water quality report →
Hardness scale
What to read next
- Do you need a water softener?Water here is very hard; size a softener with our calculator.
- How to tell if your home has a lead pipe3 service lines here are of unknown material.
- Hard water and your water heaterHow scale affects your water heater and how often to flush.
- Water hardness converterConvert mg/L to grains per gallon or °dH for your dishwasher.